Improving the efficiency of heat recovery circuits of cogeneration plants with combustion of water-fuel emulsions

dc.contributor.authorKornienko, Victoria
dc.contributor.authorRadchenko, Mykola
dc.contributor.authorRadchenko, Roman
dc.contributor.authorKonovalov, Dmytro
dc.contributor.authorAndreev, Andrii
dc.contributor.authorPyrysunko, Maxim
dc.date.accessioned2022-06-21T22:56:45Z
dc.date.available2022-06-21T22:56:45Z
dc.date.issued2021
dc.descriptionImproving the efficiency of heat recovery circuits of cogeneration plants with combustion of water-fuel emulsions / V. Kornienko, M. Radchenko, R. Radchenko, D. Konovalov, A. Andreev, M. Pyrysunko // Thermal Science : Intern. Scientific Journ. – 2021. – Vol. 25, No 1B. – P. 791–800.uk_UA
dc.description.abstract1When using modern highly efficient internal combustion engines with lowered potential of exhaust heat the heat recovery systems receive increasing attention. The efficiency of combustion exhaust heat recovery at the low potential level can be enhanced by deep cooling the combustion products below a dew point temperature, which is practically the only possibility for reducing the temperature of boiler exhaust gas, while ensuring the reliability, environmental friendliness and economy of power plant. The aim of research is to investigate the influence of multiplicity of circulation and temperature difference at the exit of exhaust gas boiler heating surfaces, which values are varying as 20 °C, 15 °C, and 10 °C on exhaust gas boiler characteristics. The calculations were performed to compare the constructive and thermal characteristics of the various waste heat recovery circuits and exhaust gas boiler of ship power plant. Their results showed that due to application of condensing heating surfaces in exhaust gas boiler the total heat capacity and steam capacity of exhaust gas boiler increases. The increase of exhaust gas boiler heat capacity is proportional to the growth of its overall dimensions. A direct-flow design of the boiler provides a significant increase in heat efficiency and decrease in dimensions. In addition, a direct-flow boiler circuit does not need steam separator, circulation pump, the capital cost of which is about half (or even more) of heating surface cost.uk_UA
dc.identifier.govdoc:https://doi.org/10.2298/TSCI200116154K
dc.identifier.urihttps://eir.nuos.edu.ua/handle/123456789/5598
dc.language.isoenuk_UA
dc.subjectexhaust gas boileruk_UA
dc.subjectinternal combustion enginesuk_UA
dc.subjectafterburninguk_UA
dc.titleImproving the efficiency of heat recovery circuits of cogeneration plants with combustion of water-fuel emulsionsuk_UA
dc.title22021
dc.typeArticleuk_UA

Файли

Контейнер файлів
Зараз показуємо 1 - 1 з 1
Вантажиться...
Ескіз
Назва:
Kornienko_V_2021.pdf
Розмір:
1003.26 KB
Формат:
Adobe Portable Document Format
Опис:
стаття
Ліцензійна угода
Зараз показуємо 1 - 1 з 1
Ескіз недоступний
Назва:
license.txt
Розмір:
7.05 KB
Формат:
Item-specific license agreed upon to submission
Опис: